Understanding the Seamless Pipe Expansion Joint Mechanics
Thermal Expansion Coefficients (α) at 300°C
| Класс материала | Coefficient(× 10-6 / ℃) | Average Expansion per 100 Meters (mm) |
|---|---|---|
| Труба из нержавеющей стали 304/304L | 17.8 | 498 |
| Трубы из нержавеющей стали 316/316L | 18.2 | 510 |
| 2205 / 2507 Дуплексные трубы | 14.5 | 406 |
| ASTM A106B Carbon Steel | 13.0 | 364 |
Что мы делаем
- Пластина
- Лист
- Поковки
- Круглый прут
- Фланец
- Трубы
- Арматура
- На заказ
Свяжитесь с нами для получения дополнительной информации
Step 1: Calculate Thermal Expansion in Steam Systems
Step 2: Determine Max Anchor Span for a Seamless Pipe Expansion Joint
304/304L Stainless Steel Pipe:Max. Anchoring Span at 250°C
| Номинальный размер трубы | Bellows Capacity(ΔLallowable) | Calculated Maximum Anchor Span(LМаксимум) |
|---|---|---|
| 3 Inches (DN80) | ± 25 mm | 31.3 Meters |
| 6 Inches (DN150) | ± 40 mm | 50.1 Meters |
| 12 Inches (DN300) | ± 60 mm | 75.2 Meters |
316/316L Stainless Steel Pipe:Max. Anchoring Span at 250°C
| Номинальный размер трубы | Bellows Capacity(ΔLallowable) | Calculated Maximum Anchor Span(LМаксимум) |
|---|---|---|
| 3 Inches (DN80) | ± 25 mm | 30.6 Meters |
| 6 Inches (DN150) | ± 40 mm | 49.0 Meters |
| 12 Inches (DN300) | ± 60 mm | 73.5 Meters |
2205 / 2507 Duplex Pipe:Max. Anchoring Span at 250°C
| Номинальный размер трубы | Bellows Capacity(ΔLallowable) | Calculated Maximum Anchor Span(LМаксимум) |
|---|---|---|
| 3 Inches (DN80) | ± 25 mm | 38.4 Meters |
| 6 Inches (DN150) | ± 40 mm | 61.5 Meters |
| 12 Inches (DN300) | ± 60 mm | 92.3 Meters |
Step 3: Calculate Pipe Guide Spacing Spans
Recommended Pipe Guide Spacing Intervals
| Номинальный размер трубы | First Guide Distance (Max) | Second Guide Distance (Max) | Subsequent Guide Spacing |
|---|---|---|---|
| 3 Inches (DN80) | 0.30 Meters | 1.05 Meters | 9.0 Meters |
| 6 Inches (DN150) | 0.60 Meters | 2.10 Meters | 14.0 Meters |
| 12 Inches (DN300) | 1.20 Meters | 4.20 Meters | 22.0 Meters |
Compliance with EJMA Standard Specifications
EJMA Maximum Intermediate Guide Spacing Based on Steam Pressure
| НПС | Operating Steam Pressure | Maximum Allowed Intermediate Spacing | EJMA Stability Safety Factor |
|---|---|---|---|
| 3 Inches (DN80) | 10 Bar | 11.5 Meters | 4.0 |
| 3 Inches (DN80) | 20 Bar | 8.2 Meters | |
| 6 Inches (DN150) | 10 Bar | 18.4 Meters | |
| 6 Inches (DN150) | 20 Bar | 13.1 Meters | |
| 12 Inches (DN300) | 10 Bar | 29.6 Meters | |
| 12 Inches (DN300) | 20 Bar | 21.2 Meters |
Troubleshooting Your Seamless Pipe Expansion Joint Span
An excessive span generates more thermal expansion than the bellows can absorb safely.As a result,the metal suffers from rapid fatigue cracking.
Да,high-velocity steam causes severe bellows vibration and localized erosion.You must specify an internal flow sleeve for steam velocities exceeding 15 m/s.This sleeve prevents the steam from damaging the internal bellows of your seamless pipe expansion joint.
High internal pressure increases the risk of column buckling along the piping span.You must reduce the guide spacing intervals significantly at higher pressures.Always consult updated EJMA tables when choosing a seamless pipe expansion joint for superheated steam.